pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
Activity Detection Device Extender: Activity output now triggers on
analog, digital, and serial activity. Join #'s below 17000 trigger
activity; joins 17000 and greater do not (as they are treated as
reserved joins).
- Alter permanent String handling: A permanent string now requires a size. If
the string ever attempts to grow beyond the size, an error is printed and
logged to the error log. Also, if a string is tied to multiple Make String
Permanent symbols, the size of the last Make String Permanent is used for that
particular string. A size of zero is disregarded if a previous size had been
assigned to that string. If a string is tied ONLY to the original style
Make String Permanent (no size given), it will behave identical to old CUZ's.
- Fixed a bug where two EISCs would have one way communications when rebooted
in close succession.
- Fixed a bug where a gateway connection would have one way communication with
the control system after an abnormal network termination (LAN cable unplugged,
in/out of WiFi range)
- Corrected a memory leak that occurred in the TCP/IP client if the program
toggled the connect line on the device when a connection failed.
- Fixed an extraneous error that arose when the webserver and SSL were both
disabled.
- Fixed the NVRAM autocompaction to where it failed to account for the file being
overwritten.
- Improved security when writing to flash.
- CTP disconnect messages appear in the console when restarting the program
with a gateway connection that had automatic reconnection enable..
- Fixed a bug where data sent from a TCP/IP Client symbol on the rising
edge of the Connect-FB was never transmitted.
- Fixed a bug where the Simpl+ FileOpen routine returned a positive error code
when attempting to write to internal flash. This sometimes allowed the file
to be written when writing to internal flash is not supported.
- Restarting the program is now properly blocked from an Ethernet slave
processor.
- Fixed a master/slave bug that showed configuration pipe error messages on
the slave when the master is reset.
- Corrected a problem for slave processors that lead to eventscheduler que
error messages (the error message was "que deleted" which was correct, and not
harmful, but annoying to see). This was sometimes seen when the master
program was reset.
- Fixed a bug where the internal flash file system was not loaded if the NVRAM
disk was found to be corrupted.
- Fixed a bug in reporting slave system states back to the master.
- Changed the file error codes to be more consistent with the code documented
in the Simpl+ manual.
- Fixed a bug where a mismatch route symbol (if there was no E for C or C for
E) was only reported on system reboot, but not on F10.
- Fix crash/reboot if the program was stopped and you hit the COM button on
the front of the rack.
- Fix touchpanel chaining so that "unexpected packets" are no longer
encountered (even though the chaining worked).
- If an Ethernet slave is not in the IP table but in the program, do not
attempt to configure it. (You will not get the slave configuration timeout
message).
- Add/move checks to be sure if a signal is actually an analog when packing
up RCB's when signals change (not an update request). This fixes issues
where analogs & digitals arrived in the same wave @ the CLW symbol and
caused a SetSize() error on the console.
- Avoid sending UDP data when the DHCP address has been released.
- Fixed a crash when the processor received a CIP message from a device not in
its IP table.
- Fixed a crash that occurred when two UDP devices were using the same
port and the program was restarted.
- Fixed a bug where, if the master ever received a slave configuration
timeout, if would never configure the device until the master was