pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
- Modified the offline extender for Ethernet panels so that it is no longer
necessary to write data to the device to determine that it is offline.
- Modified the output of the WHO command to display the amount of time
each device was connected.
- Added the total number of errors logged and display this at the end of the
error log report. This is to indicate whether any errors have rolled off the
beginning of the log.
- Fixed control system lockups and crashes experienced using TPMC-10 panels.
- Fixed a problem where the system would reboot when processing the ESTATUS
command while receiving Ethernet traffic.
- Fixed a lockup seen when restarting a program from compact flash.
- Fixed a problem with indirect text when using indirect text append symbol
with Mode 0 (standard mode) where 2 extra characters would show up before the
text (a "garbage" character and a zero). This would happen with XPanel &
older TPS panels.
- Fixed a problem that made Toolbox believe that compact flash was available
even though it was not properly initialized (media insertion error).
- Fixed a problem where multiple concurrent file writes to NVRAMDISK would
cause the processor to reboot and corrupt the NVRAMDISK. Also fixed a problem
where the NVRAMDISK could be corrupted during program restarts.
- Improvements to the EISC symbol to increase the number of signals that can
be handled (1000 digitals, 1000 analogs, 1000 serials).
- Fixed CIP OFFLINE messages for CIP devices (EISCs, Ethernet slave
processors, etc).
- Fixed SIMPL+ Precision width specifiers for strings, i.e. %25s (right
justified field; padded with leading spaces), %-25s (left justification,
padded with trailing spaces).
- If a slave device is not registered (i.e. there is no IP table entry
matching the program), skip printing error messages when trying to send data
about "no pipe exists".
- Changed IP table status so that the Node type field of an IP table entry
reverts to "NOT REG" when a program is stopped.
- Fixed Serial IR mode 7 bit character generation.
- Fixed crash with SIMPL+ WAIT() and DELAY() statements when the time
parameter was > 429496.
- Fixed "Slave Pipe" errors when the device wasn't registered, goes offline (&
the master is rebooted), or the configuration failed for some reason.
- Added LISTDNS from user programs.
- Added option "-L" to CLEARERR to only clear the LED (i.e. "CLEARERR -L").
This will turn off the LED but still leave the errors in the log for later
retrieval.
- Activity detection helper now works with UPX-2 and TPMC panels and TSTATs.
- Added the VNVRAMCLEAR command to clear the NVRAM without a confirmation
step. This is designed to be utilized from a program.
- Change the Clockdriver symbol to check for multiple non-zero DST drivers.
Only uses the first non-zero value.
- Fixed a crash when heavy ramping activity was done through the ABUFFER
symbol.
- Fixed a crash in Super Debugger that occurred when turning debug on/off for
Slots or Ethernet.
- Fixed problem when processing the serial data from an C2N-TXM when no digital
outputs were defined on the C2N-TXM device symbol.
- Fixed a problem on with RCBs where on occasion a signal would "stick".
- Fixed a bug in the Analog Increment symbol where if LowerLimit was > 0, and
Increment was <= LowerLimit, and UP was held, the symbol would go to the
LowerLimit and stay there. You would have to release UP and press it again to
get it to repeat.
- Fixed a crash that occasionally happened when using the SIMPL+
CancelAllWait() function.
- Added a limit to the size of the error log on CF. This was to avoid the
large delay that could occur when writing to the end of the large error log.
Type "CFLOGERR ?" for help on the new options.
- Corrected a bug in the Cresnet offline manager.