pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
-Now generate a notice in the error log when a Client/Server device connection
status changes.
- Fixed a bug where Gateway connections were retained through program reset.
***Since Version 1.017 (Release)
-Corrected a low-level problem where the internal operating system lists were
corrupted and caused the system to hang-up. Problem only manifested itself under
heavy Cresnet or Ethernet traffic while using Simpl+ PULSE() statements.
-Improved the UPLOAD command.
-Improved the handling of bus timeouts and spurious interrupts.
-Improved handling of off-line devices. Once a device is considered offline, the
system will not try to send it any more data. This will eliminate the error
messages when writing to a device that is off line.
-Added a better error message for IR queue overflow.
-Handle zeros(0) on the output of the XSIG symbol.
-Fixed a crash that occurred when closing a socket that was never openned.
-Fixed a front panel problem where temporary messages would not go away.
-Modified the TVAV driver to ignore type 04 packets.
-Improved handling for unknown/unexpected packets.
-In the broadcast symbol, fix offset-by-1 problem (field 1 was being sent as field
2, etc...)
-Improved support for the CNX-TA card.
-CIP devices are now sent the CIP resync flag upon update request.
-Fix lighting symbol packet output when non-RCB analogs and RCB analogs are mixed in
the same wave on the inputs.
-Added new command WHO to display the active Ethernet connections.
-Improved Simpl+ tasks management.
-Generate a registration error if no IP entry for a TCP client or server device.
-Changed TCP ClientServer driver to only send serial data if a connection is made.
-Fixed a crash when closing a TCP Client symbol both remotely and locally.
-Now handle the RING response from the console modem as a special command.
-Suppress extra error messages if a CIP device is offline.
-Added routine to print all the instances of a Simpl+ module.
-Added a new error message if instantiation of the Simpl+ instance fail because of
NVRAM allocation.
-Changed Signal_s structure to past last modified array index to the event
handler. This will handle the case when multiple elements of a Simpl+ input
array are triggered at the same time. GetLastModifiedArrayIndex will now
report the correct signal. (REQUIRES AN UPDATED VERSION OF INCLUDE.DAT FROM
SIMPL WINDOWS).
***Since Version 1.016 (Release)
-Fix problem with the Poll Manager Device Extender where the poll-inhibit did not
work properly. (Still will not work for the CPC-CAMI. Requires a change to SIMPL
Windows)
-Fix problem where packets intended for the internal cresnet driver were being put
on the wire when sent from an NTX symbol
***Since Version 1.015 (Release)
-Modified the Ethernet driver to handle high traffic systems better.
-Adjusted the priority of the web server to be more consistent with other tasks.
***Since Version 1.014 (Release)
-Fix problem where a CEN-COM would not not communicate properly after the control
system reboots
-Prevent crash when a TCP/IP Client or Server device does not have an IP Table entry
associated with it
-In SIMPL+, prevent possibility of events being triggered before the main() function
has a chance to run
***Since Version 1.013 (Release)
-Remove delay between characters for one-way serial out of an IR port (introduced in
1.012)