Request AudioReQuest Z.Series Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
the current integer value.
-In Serial RAM, make dial output go low after any of the select inputs go low
-Fix problem with Non Volatile Ramp where the value would always go to 100% on
program start
-On program initialize, delay start of ramping operations until all symbols have
been initialized
-During program initialization, make dots ('.') appear when connected to the control
system via ethernet
-Fix problems with CNX-TA card
-File system compaction now suspends the program before compaction and then resumes
the program after it is done.
-More improvements to TPS passto
-Fix problem with MXB where if the result should be negative it would show as 65535
instead
-Fix Potential lockup with over 200 delays triggered at the same time and expiring
at the same time
-Fix STRFGWX lockup when an empty string is sent to an indirect text field on an
STX-1550C.
-Fix Problem where an error is reported if the 1 or 0 signals are routed to analog
or serial inputs or outputs on a SIMPL+ module
-Prevent Erroneous messages from being reported from Device Extenders.
-Fix problem where the "PANEL" butoon on the PRO2 Main Menu would not appear after a
program transfer if the program contained SIMPL+.
-Fix problem when clearing the error log from the front panel where if user front
panel pages existed, the first user page would appear after releasing the "YES"
button to confirm deletion of the error log
-Fix Problem where an oscillator with a high time and low time of 1d or .01s will
cause the system to appear sluggish
-Fix problem where after running selftest, allocation errors would be reported while
restarting the program
-Fix Problem in SIMPL+ reading back analog output values
-Change the format of the error log
-Fix problem where if the output of a ramping symbol (ramp, slew, preset, etc.) was
tied to the output of an Analog Buffer, the ramping operation would be stopped when
the enable of the Analog Buffer went low
-Fix problem where SIMPL+ instance name was appearing as garbage when errors were
printed from SIMPL+ modules
-Handle putting error messages from remote devices (e.g. Framing error from ST-COM)
into the error log
-Fix problem where the ST-COM would not work properly until its power was cycled
-Fix problem with odd parity on internal COM ports A and B
-Fixed problem where refreshing web pages with no IP table entry would crash the
system.
-Fix problem where transferring files to a TPS panel while some other cresnet
devices were on the network (e.g. LC-1000, CT-1000) could cause the transfer to fail
-Fix problems transferring files to a CNX-TA card when connected to the control
system via TCP/IP.
-Fix problem with clearing error log
-Added a check for NULL destination pointers in Simpl+ makestring calls.
Page 23
Vista de pagina 22
1 2 ... 18 19 20 21 22 23

Comentarios a estos manuales

Sin comentarios