pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
through the console symbol, it's output is > 255 and got chopped off.
- Corrected a problem where relays were missing short pulses.
- Fix crash where RF Gateway was defined in program with no transmitters
defined & a packet was received.
- Fixed a problem where files written to compact flash would not truncate
properly. That is, if a smaller file of the same name was sent, the old data
would be left at the end of the file.
- Fixed a problem when trying to search a directory that does not exist from
Simpl+ routines.
- Fixed a crash when a Simpl+ Wait Event expires while trying to start the same
event.
Version 3.015 (Release)
Nov 08, 2002
- Sending an email message from Simpl+ with the SendMail() function call now
supported. Unauthenticated and "Clear Text" login authentication is
supported.
- eControl 2 now supported with the external (software) gateway and the
internal gateway of 2-series processor. (REQUIRES AN UPGRADE TO THE SOFTWARE
GATEWAY)
- Fixed bug in "Analog Scaling Buffer" and "Analog Scaling Buffer
about 50%" that would lead to the output continuously ramping even if the
input ramping function had stopped.
- Fixed a condition in the logic processor that lead to a symbol queue overflow.
- Improved handling of Ethernet devices coming back online.
- Modified Cresnet timing to avoid overrunning the ST-VC
device. This corrected a problem where mute messages to the ST-VC were lost.
- Soft reset symbol (RESET1) will now function correctly.
- Now issues a stop on when the IR queue overflows. Only on the new 2-series
type IR devices.
- Fixed a bug with the initialization strings for CPC-CAMIs on an Update Request.
- Fixed memory leak caused by the STRINGIO symbol when a RX$ was defined and
there were no match (output) terms defined. Activity on RX$ would cause
memory loss under this condition.
- Modified how files stored on the internal flash were served. This fixes a
problem that arose with IE6 w/ SP1 and serving web pages from a 2-series
processor.
- Fixed a problem handling high number of IR packets to a room box/tvav.
There is now a limit of 64 functions that can be queued (realistically, 32
start + 32 stop). The "IR Queue overflow" message is now issued if the limit
is exceeded. The previous contents of the queue are dumped and the new
function goes into the queue.
- Change to allow SBUFFER symbol to propagate analog values ALWAYS even if
the value has not changed (X Gen compatability).
- Fixed a bug where a Simpl+ event could be triggered before the module is
fully initialized. This would lead to a "Could not send signal to event
handler" error message.
- On the XSIG symbol, Remove "Invalid Signal Number" error messages. This was
confusing because an XSIG can receive an out-of-bounds signal number when
offsets are used. Since the message can cause confusion, it was taken out.
(i.e. a serial signal going to an XSIG with offset 0, an XSIG with offset 100,
etc... signal 105 causes an ùerrorù on the offset 0, but not on the second)
- Also on XSIG, Fix analog encoding (only potentially showed up for signal #
> 127 on the XSIG or if the offset is big enough to make the signal # greater
than 127). Fix bug with Option==1 & Option==2 where if a transition for the
same signal was present more than once on the RX$, it would cause ùCannot
Solve Logic within 1000 wavesù error. This does NOT affect Option==0.
PostProcessing was messed up (was adding the RX$ to the intermediate$ causing
an ever-growing string to be processed).
- Fix for all TVAV derivatives: CN-TVAV, CEN-TVAV, CNX-RMC, CNX-RMCLV where
the wrong IR code would go out, sometimes causing the IR port on the box to
Page 16