pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
was enabled and an IP packet was received.
Build: 3.061(Release)
July 21, 2003
- SSL now implemented for the console port and the web port.
- Support for the new CLW dimming modules.
- Full support for the Network poll accelerator (NPA8).
- Corrected a problem with Test Manager where large programs would reset the
processor during the resync process.
- Modified the NVRAM disk to be more compatible with CF. Handle TRUNC, APPEND &
RDWR file open flags.
- Now return the contents of the root of compact flash when "\\CF0" is supplied
as a path for FindFirst.
- Fixed a bug with Simpl+ Wait statements where it would give an error message
"Could not retrieve TimerDone flag in WaitEventTask" during normal operation
in heavy system load.
- Fixed a problem in the task scheduler that lead to Simpl+ event timeouts.
- Fixed a bug that allowed both Ethernet devices to be set to the same subnet.
- Corrected problems with route symbols. Enhanced the route symbols
to handle mismatched list sizes.
Originally, C's and E's treated all the inputs as one group, and said First
signal on the ROUTEC input goes to the first signal on the ROUTEE output, etc.
Now, you don't have to have the exact same # of analogs, digitals, and serials
on the input of a ROUTEC and the output of a ROUTEE. It now bases it off of
position within the list, rather than absolute position, so the first analog in
the ROUTEC goes to the first analog output of the ROUTEE. The first serial in
the ROUTEC goes to the first serial output of the ROUTEE.
This also should fix the issue causing a system reboot when the list sizes were
mismatched.
Ex: If you define (on the input of a C):
Digital input 1,2,4,5
Analog input 3,4,7
Serial input 6,8
...And on the output of an E:
digital output 1,2
analog output 3,4,7
serial output 8
... And if you were to drive analog input 3 on the C, you will now get out the
value on analog output 3 of the E. Before it wouldn't work. It does now.
- Fixed the SMV similar to CSym_Mv where input would trigger and output would
not go high.
- Changed the route symbols to fix problem where "Disconnect all E's from
current C" or "Disconnect all C's from current E" would not disconnect all
connections - it would sometimes take 2 hits (or more) to disconnect all.
- Removed a debug statement that would trigger if reset was high - MV or RMV.
- Modified the XMODEM routines to be more robust. Fixed problems that
surfaces over slow/lossy Ethernet connections.
- Fixed a problem where IP table enteries were marked "UPD PEND" when they
full functional.
- Block serving user pages from a slave processor.
- Added code so that 2-series processors as Cresnet slaves will issue an update
request after exiting PassTo mode.
- Corrected CNETID command for slave mode: no reboot needed to change cnetID