pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
- Fixed problems with lightng modules not always correctly getting 0s RCBs.
- Fixed SELFTEST where "SELFTEST SLOT x" did not work from an Ethernet console.
- Now bypass reading the IP table if program is bypassed.
- Now log disconnects of Ethernet consoles with SHOWEXTRA.
- Fixed a bug where CIP nodes where marked for DNS lookup erroneously.
- Fixed a bug in the ABUFFER: If the ramping process on the input is of
short enough duration, a lighting module attached to the output of the ABUFFER
(or further down the line from the ABUFFER) may not see any transition - i.e.
no activity on the light. This is very evident with a 0s preset but it can
happen otherwise. Quick button presses of a ramp typically do not look like a
problem, however, if something like a ramp is very near it's endpoing when the
ramping process is activated, and the natural endpoint would occur during the
duration of the button press, you would see no transition. Also fixed when
a ramping process is terminated (such as lifting your finger from a ramp - NOT
the ramp naturally halting when it hits an endpoint) on the input of the
abuffer, sometimes the output ramping process is not killed and the lighting
module may not stop it's fade.
- Corrected the PRESET/PRESET2/PRESETV: Cuts are now fixed (hitting the
same preset for a second time should go to the final value in 0s time).
- Fixed a problem with the CNX-RMC, CNX-RMCLV: There were issues with no IR
or the wrong IR being emitted under certain circumstances, such as driver
configurations like:
AAC
AC
(i.e skipping ports and doubling up on ports with skips in between)
- Fixed issue with ABUFFER, SBUFFER, MBUFFER, MBUFFER2 where if a ramping
process was on an input (i.e. from a RAMP, PRESET, PRESETV, etc.) and the
output was tied to "0", the system would crash.
- Fixed the WEBPORT to handle the user entering a 0. Generate an error
message.
- Fixed a problem with SMEM symbol where NVRAM would be overwritten. Evident
with multiple SMEM symbols.
- Corrected a problem with the ARAM symbol where STORE & RECALL were high and
a select changed - this now will recall the value in specified select for
generation X compatibility. Fixed issue where symbol would recall values in
given select on the negative edge of RECALL as well as the positive edge.
Version 3.030 (Release)
Feb. 7, 2003
- Fixed a problem in the PAC2 where the LED for LAN B and ACT B did not work
in selftest.
Version 3.029 (Release)
Jan 30, 2003
- Full support for PAC2, lighting and D3 Pro.
- Touch settable IDs now fully supported.
- Removed the printing of com port errors directly to the console.
- Added error codes from the Simpl+ wrapper for SendMail.
- Corrected a bug with the TCP/IP Client Device where it would not always
reconnect properly. Also added a 0.5 second delay before the client
reconnects so that the CONNECT line could be dropped. This helps the
situation when connecting to a server that disconnects automatically.
- Moved the logging of connects and disconnects for Client and Server devices
under the control of the SHOWEXTRA command. That is, the connects/disconnects
will only appear in the error log is SHOWEXTRA is enabled.
- Fixed a bug where Simpl+ functions PauseWait()/ResumeWait() would restart the
wait timer from 0 instead of when it was paused.
- SIMPL+: IsSignalDefined() works properly for 0's placed on digital inputs and
outputs.
- Added new command (TELNETPORT) to enable/disable the Telnet port. The
default is enabled.