pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
***Since Version 1.012 (Release)
-Fix problem introduced in v1.012 where the net button on the front panel would
never report any devices
-Fix timing issues when transferring firmware to devices with smaller processors
-Fix problem where the CNXIO-16 card could cause bus timeout errors
-Improved error handling so that once a cresnet or ethernet device goes offline,
errors won't be generated trying to transmit to that device until it comes back
online
-Improved handling of Update Request messages from devices to prevent system
slowdown when network errors exist (e.g. when two devices have the same cresnet ID
and an ST-IO or CNX-PAD8 is on the network)
-Improve error message for IR queue overflow.
-Increase IR queue so that a minimum of 32 commands can be sent at a time to any IR
port
-Fix problem detecting a multi-code IR function in a driver if the function did not
have the default minimum repeats
-Fix problem where system could lock-up on reboot or program reset if the program
took more than 5 seconds to load from flash. This effected programs where the .bin
file exceeded 850 KBytes.
-Fix lock-up that could occur if the connect line on a TCP/IP Client/Server symbol
is dropped low before the connection occurs.
-Add short delay between sending IR functions on the same IR port when those
functions were triggered at the same time in logic. This is to be compatable with
previous generation control systems.
-In the Intersystem Communications symbol, do not report a signal mismatch error if
a serial or analog output is tied to the '0' signal.
-When debugging serial signals, only show the first 256 bytes of the string in Test
Manager. This prevents the display of the "TxConsoleData: Error writing to
Tx2Pipe." error message that would occur if a longer string was sent.
-When reporting an error message that a cresnet packet is too big to be transmitted,
only show the first 20 bytes of the packet.
-In SIMPL+, make sure that the main() funtion runs before any event runs-Improve
detection of a corrupt file system at startup
***Since Version 1.011 (Release)
-Improved handling of IR overflow
-Fix timing problems with CNRFGWA (This appeared as an ST-IO that would frequently
send Update Requests when a CNRFGWA was on the cresnet network connected through a
CNXHUB)
-Fix problem with Memory Interlock symbol where the clear input had to have a signal
attached to it (it wasn't being treated as optional)
-Fix problem with TPS-RF panels where the outputs of the symbol would be cleared
when the panel issued an update request
-Fix problem where if Compact Flash was inserted and the current program had a 1
tied to a front panel page jump, the front panel would be left showing the "Compact
Flash Initialized" message on reboot.
***Since Version 1.010 (Release)
-Fix problem where if a SIMPL+ module is adding over 100 signal transitions where
one or more signals have multiple transitions within its initial timeslice, the
logic processor could get into a deadlock situation
-Modified certain error messages from Simpl+ to only be warnings instead of errors.
-Modified KILLPROGRAM to just delete the program from flash and not stop it. Use
STOPPROGRAM to stop the program after erasing it.
-In SIMPL+, changed the level of error messages for invalid signal index and string
overflows to WARNING.
-Changed the error level for console break detection to NOTICE.
-Add IR test to SELFTEST in CP2/CP2E
***Since Version 1.009 (Release)
-Fix problems with Ethernet Virtual Com Port device
-Fix crash that resulted from pressing a button on the RF mouse when no signal is