pro2_av2_cp2_cp2e_rack2_pac2_4.003.0015.txt
lock high or not work. This could ONLY happen if you had multiple drivers
stacked on ports. An assumption was made that Port=Child Index 0, B=1, etc.
If you have multiple drivers, this no longer makes sense. NOTE: Future
revision needed to handle index '0' returned from GetParamIntegerValue()
[maybe return -1 or something?]; however the first fix will prevent the 2nd
from happening.
- Adjusted Cresnet Driver to elminate "RX error -50".
- Added a progress indication for program destruction ("Termination
Cleanup") and also for loading symbols ("Loading").
- Fixed a memory allocation bug that would lead to a slow down of the system.
- Added additional checks to the NAT portmap configurations. Check for the
same external port mapped to two different places.
- Corrected a problem with the NAT configuration pages where the reboot button
was not actually rebooting the system.
- Modified Cresnet passto timing to handle the TPS2000 reentering passto after
reboot.
- Added additional error messages to the logic processor.
- Corrected a crash in the Event scheduler when an event expires and gets
deleted by the symbol at the same time. (i.e. trigger a DELAY & resetting it
could cause this)
- Fixed a crash when selecting passthrough to a non-existent cards (i.e.
wrong slot number).
- Added a check to make sure that the port selected in the WEBPORT command has
not be remapped by the NAT.
- CNX-COM2 cards firmware upgrades now supported.
- Corrected a problem with Simpl+ WAIT statements that would use up memory and
eventually reboot the processor.
-Prevent "clear all" from being transmitted to CEN-TVAV/CN-TVAV/CNX-RMC/
CNX-RMCLV when the system receives an update request from such a device. This
resolves an issue, specifically with the CNX-RMC having all of it's video
inputs disabled when an update request was performed.
-Support for Analog Min/Max symbol. Requires SIMPL Windows Library Update
180 or later.
-Fix Analog Buffer & Serial Buffer so that the output ramping process stops
when the enable is driven low & there is a ramping process on the respective
input.
-Fix CEN-TVAV/CN-TVAV versiports & current sense. They now correctly register
HIGH when 1-4 is shorted or power is sensed on the outlet, and low otherwise.
- Changed the firmware name reported for the C2Y-COM3 card to
C2COM-3 for consistancy with the product name.
- Compact flash file system now handles deleting long file names.
- Fix operation of Serial Pacer symbol so that if a string comes into the
symbol while it is currently pacing out data, it no longer causes garbled
output or never-ending output.
- Fixed problem with "\r" as the last character of a field causing text like
"#1," to show up on thedisplay of the touch panel.
- Cresnet devices now accessible for CEN-TVAV (slave mode) and CEN-CN.
- Lighting support including Analog Comparisons (Full Set), Multiple Preset,
CLX-xDIMx, CLX-1MC4, CLX-4HSW4. SIMPL Windows Library update 180 or later is
required to use these symbols.
- Fixed a problem with CNX_I016 driver where the card would not respond.
- Fixed Memory Interlock so that CLEAR isn't needed. Also, all outputs are
mandatory now.
- Fixed analog signal encoding on XSIG so that values > 16383 are properly
encoded.
- Improved NetAnalyze performance when more than 8 devices on the network.
- Handled a crash where the password verification failed for Ethernet
consoles. Only 3 password attempts are allowed now (down from 4).
- Corrected a problem with older CNWM-10A panels where the panels would
continuouly reboot. This change is across all CNWM type panels.
- Added support for the Selective Clear-all for TPS touchpanels.
- Fixed the web server to handle excessively long URLs used in web attacks.
Changes made to the webserv code to make it more robust.
Page 17